- Product Categories
- Friendly Links
Information Name: | Assembly line production of electronic billboards |
Published: | 2014-12-25 |
Validity: | 360 |
Specifications: | 1700mm * 1000mm * 300mm * 70mm |
Quantity: | 1.00 |
Price Description: | |
Detailed Product Description: | Shenzhen's Peng Technology Co., Ltd. is focused on LED electronic billboards in high-tech enterprises, the main production of billboards, LED oil screen. The main services are: billboards in the development, production, sales, production systems and production Kanban Kanban software application and promotion, LED oil screen control card, LED oil screen system solutions, LED oil screen accessories. LED electronic billboards has achieved national sales leader, and establish a high-quality LED screen brand prices. In addition to producing oil billboards and LED screens, news Peng successfully used in outdoor LED electronic billboards electronic clock, temperature and humidity display, clock display, exchange rate screen, countdown, safety record cards, electronic prices cards, electronic gold card, watch display , scoreboard, etc. 1. The target output is automatically incremented according to the cycle time. 2. invested and mantissa count by photoelectric switch. 3. accumulated for actual production within the planned production date, namely the actual production capacity count, total count also. 4. The actual production according scanner count 5. Press [Esc] screen soft shutdown, then showed normal one, edit the work order number, the target output, actual output, total output ① Press [Edit], then the cursor in the work order the number of bar flashes; ② Press [F1], the upward movement of flashing menu; ③ Press [F2] to the left to move the flashing menu; ④ Press [F3], the right to move the flashing menu; ⑤ Press [F4], down to move the flashing menu ; ⑥ flashing menu at the numeric keys to enter data; ⑦ press [ENTER] to save data and exit; ⑧ Press [ESC] to cancel this operation and exit; Note: The actual output count by scanning gun; two, edit input number of standard production capacity, standard human, real human, ending ① press [Esc] + [Edit] The cursor blinks in the work order number column;. ② Press [F1], the upward movement of flashing menu; ③ Press [F2] to Left to move the flashing menu; ④ Press [F3] to the right to move the flashing menu; ① Press [F4], down to move the flashing menu; ② flashes Menu by numeric keys to enter data; ③ press [ENTER] to save data and exit ; ④ Press [ESC] to cancel this operation and exit; Note: photoelectric switch inputs by counting the number of mantissa, put the number of columns displayed in the work order number / standard production target output is displayed in the column, the standard human displayed in real output Bar / actual manpower column displays the cumulative output, ending the current efficiency is displayed in three columns, editing time ① Press [Time], then the cursor blinks at the time bar; ② Press [F3] to the left to move the flashing menu ③ Press [F2] Move the flashing menu ④ flashes Menu by numeric keys to enter data; ⑤ Press [ENTER] to save data and exit; ⑥ Press [ESC] to cancel this operation and exit; Note: Entering an invalid time will automatically restore the current settings The effective time is automatically updated four weeks, cleared cumulative output, ① Press [Del], cumulative output bar is flashing; ② press [ENTER], cleared save data and exit; ③ Press [ESC] to cancel this operations and exit; five, clear target yield, actual output, input the number, ending ① Press [F2], the actual output bar is flashing; ② press [ENTER], cleared save data and exit; ③ Press [ ESC] to cancel this operation and exit; Note: a number of inputs and mantissa for hidden data. 2. Press the [Esc] + [Model] to enter each time period count data is automatically cleared or accumulate settings (such as: today the first time the actual output is 100, the first time tomorrow, the actual production whether accumulate to 100); F1.F4 press [] to switch the first time the work order number column shows "1", "0"; ("1" does not automatically cleared to "0" indicates automatically cleared zero) six, set the step length, photoelectric closing time, the delay time ① Press [Step], then the cursor bar flashes in the work order number; ② Press [F4], down to move the flashing menu; ③ Press [F1], ④ flashing upward move flash menu Menu by numeric keys to enter data; ⑤ Press [ENTER] to save data and exit; ⑥ Press [ESC] to cancel this operation and exit; the step length, step = enter 0001 1 , count, count every time, the number of plus 1; 0005, said input step = 5, count, count every time, the number of plus 5; closing time: valid time the switch is closed, the work order number is displayed in the column number of the second line Example: closing time is set to 000.1, the time of the switch closure time must be greater than one second to be effective in less than one second switch off count as invalid; delay time: The minimum interval between the second count is displayed in work order number column third row; for example: delay time is set to 01.00, the time for the end of the last count, less than one second switch is closed as invalid (to ensure that the count properly, according to the actual value of the input, the unit 0.01 seconds;. seven, set the machine ID ① Press [ESC] to enter the soft-off state; [.] ② Press the decimal point in the target yield cursor bar flashes, ③ flashing menu at the numeric keys to enter the data; the maximum setting 255 ④ Press [ENTER] save data and exit; ⑤ Press [ESC] to cancel this operation and exit; Note: models are the rest of the screen with the 200G card card communication, do not alter the address defaults to an eight, set the tempo time ① Press [Speed ], the work order number column is flashing; ② flashing menu at the numeric keys to enter data; ③ press [ENTER] to save data and exit; ④ Press [ESC] to cancel this operation and exit; Note: Input 010.0 representation ten seconds target output corresponding period nineteen automatic reset parameters ① press [Esc], the host is powered off state; ② Press [Space], the host is in full flash state; ③ press [ENTER], to reset the data and exit (cycle time = 0; stepping length = 1, the interval and delay time = 00.01); ④ Press [ESC] to cancel this operation and exit; ten, do not set the line, the work order number ① Press [Model] enter the settings menu cursor blinking dot at; ② F3.F2 press [], the cursor moves one position to the left; ③ Press [F2], move the cursor to the left one position; ④ at the blinking cursor, via digital multiplex using the key, enter numbers or uppercase letters, each numeric key three other letters or symbols multiplexing can press the number keys to switch each other again; eg: Press number key [1], dot matrix digital display "1 "Press this button again to switch to the letter [A], dot matrix display uppercase" A ", followed by one input; ⑤ Press [ENTER] to save data and exit; ⑥ Press [ESC] to cancel this operation and exit; Note: Press [Space] hidden numbers and characters; |
Admin>>>
You are the 4270 visitor
Copyright © GuangDong ICP No. 10089450, Shenzhen's Peng Technology Co., Ltd. All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility
You are the 4270 visitor
Copyright © GuangDong ICP No. 10089450, Shenzhen's Peng Technology Co., Ltd. All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility